What's New


Model 1220 Automated Humidity Generation System

Thunder Scientific’s product line continues to deliver outstanding performance while delivering some of the tightest uncertainties available in today’s market by utilizing the fundamental “two-pressure” principle. With the discontinuation of Thunder Scientific’s Model 1200 humidity generation system, many users have been left without a suitable system that is both mobile and capable of delivering tight uncertainties required to support their metrology programs. To meet this continuing need, Thunder Scientific is pleased to announce the newest addition to its product line: the Model 1220 Humidity Generation System.

Model 1220 Automated Humidity Generation System

Model 1220 Automated Humidity Generation System

  • Includes Calibration Traceable to SI
  • RH Uncertainty: 0.6% of Reading (Range: 10 to 95 %RH)
  • Temperature Uncertainty: 0.031 °C (Range: 5 to 60 °C)1
  • Frost Point/Dew Point Uncertainty: 0.05 °C FP (Range: -22 to 0 °C FP)1

    0.08 °C DP (Range: 0 to 50 °C DP)1

  • No Refrigerants – Thermoelectric Cooling/Heating
  • Test Chamber Dimensions: 8” x 8” x 8”
  • Multi-point Touch Display
  • Easy to Use and Can be Calibrated by the User
  • ControLog Embedded Automation Software
  • Data automatically retrieved and stored in a spreadsheet style format
  • Multiple graphs for visual representation of data
  • Auto Profiling feature for automation
  • Customizable device connections for ASCII based serial devices
  • Physical Dimensions: 16.1” (H) x 27.9” (W) x 19.2” (D)
  • Weight: 150 pounds
  • Input Power of 100 to 240 VAC, 50/60 Hz, at 5 amps

If you have any questions please Call sales at 1-800-872-7728 or send an
E-mail: sales@thunderscientific.com.

Click here for more info.

1 Uncertainty values represent an expanded uncertainty using a coverage factor, k=2, at an approximate level of confidence of 95%.


Model 3920 Automated Low Humidity Generation System

Thunder would like to introduce the next generation of the model 3900 to its brand-new Model 3920 series generator which began delivery in the first quarter of 2020. This system provides precision frost point/dew point control with new style Ultrahigh-Purity diaphragm valve components as well as Thunder's own ControLog® Embedded Automation Software and features a Multi-point Touch LCD screen and new keyboard interface for ease of data input. Also includes a higher flow capability of 10 liters per minute.

Model 3920 Automated Low Humidity Generation System

Model 3920 Automated Low Humidity Generation System

  • Traceable to SI
  • High Flow Capability of 10 L/min
  • Based on NIST Proven "Two-Pressure" Principle
  • HumiCalc® with Uncertainty Mathematical Engine
  • ControLog® Embedded Automation Software
  • Generate: Frost Point, Dew Point, PPM, %RH
  • Calculated Real-Time Uncertainty
  • Multi-point Touch LCD
  • Additional Keyboard Interface
  • Calculated Water Capacity to Indicate Water Usage

If you have any questions please Call sales at 1-800-872-7728 or send an
E-mail: sales@thunderscientific.com.

Click here for more info.


Model ACS3920 Air Compressor System

The ACS3920 Air Compressor System with integral CO2 Adsorber/ Air Dryer provides a clean, dry, continuous duty gas supply for the Thunder Scientific Low Humidity Generators. The ACS3920 Air Compressor System consists of a vibration isolated oil-less compressor, membrane air dryer, CO2 Absorber/ Air Dryer, and adjustment regulators, all incorporated into a sound muffling enclosure. The ACS3920 is ideal for laboratory use due to its small size, 100 psiG pressure output at 10 L/min, with an ambient pressure -73 °C FP, 100% duty cycle capability, and a low sound level of less than 70 decibels.

For questions you may have Call sales at 1-800-872-7728 or send an E-mail: sales@thunderscientific.com.

Click here for more info.


Model 4PHM Heated Manifold Accessory

The Four-Port Heated Manifold Accessory is a commercial-off-the-shelf manifold that has four 3/4"-16 straight thread adapters standard and can be modified to fit your needs. With power applied the heated manifold automatically controls the temperature of the manifold assembly from ambient to 60 °C to aid in the dry down process of the frost point/dew point probes being calibrated. The manifold is equipped with a back-pressure regulator to allow the user to control the back pressure of the manifold above ambient pressure if desired. The manifold supports flow rates from 1.0 to 4.0 SLPM and uses adaptable inlet and outlet fittings to make the connections to your device.

For questions you may have Call sales at 1-800-872-7728 or send an E-mail: sales@thunderscientific.com.

Click here for more info.


Model 2900 Automated “Two-Pressure” Humidity Generation System

Thunder is proud to announce the new release of the Model 2900 Automated Humidity Generation System.
The Model 2900 Automated Humidity Generator is an extremely accurate means of producing known humidity values for calibrating and verifying humidity instrumentation. This system is based on the NIST proven, fundamental “two-pressure” principle.

Model 2900 Automated Humidity Generation System

Model 2900 Automated Humidity Generation System

  • Traceable to SI
  • 0.5% of Reading RH Uncertainty
  • High Flow Capability of 50 L/min
  • Based on NIST Proven "Two-Pressure" Principle
  • HumiCalc® with Uncertainty Mathematical Engine
  • ControLog® Embedded Automation Software
  • Generate: RH, DP, FP, PPM, Multipoint Profiles
  • Externally Driven Chamber Fan
  • Multi-point Touch LCD
  • Fluid Jacketed Chamber Door
  • Window Chamber Door Option Available

If you have any questions please Call sales at 1-800-872-7728 or send an E-mail: sales@thunderscientific.com.

Click here for more info.


Congratulations

Great Job Technicians!

Congratulations to both Rudy and Lemuel for achieving the goal attaining their certificates from ASQ for the Certified Calibration Technicians test. The staff and management at Thunder congratulate the both of you for accomplishing the requirements needed to complete the exam to give both you and Thunder the added benefit of the knowledge gained by getting this certification.

Left pictured is Rudy and right is Lemuel.



Also New


2500 Funnel Set

A must have for all 2500 system users, this set means you will never get mixed up as to which funnel goes where. On the Reservoir Funnel, pictured right, you know it's the right one because it has a nut attached right to the funnel, so no spills anymore. On the Chamber Funnel, pictured left, just slide it on the chamber fill port until it bottoms out, once you do this you can check the fluid level with the funnel its self by observing if the fluid touches the bottom of the funnel.
2500 Funnel Set

For a short time if you purchase this set you will receive a Free chamber fluid fill gauge and flashlight.

Ask for Free fluid gauge and flashlight combo.

E-mail us at: sales@thunderscientific.com

Need Help Getting Started?

Request a Quote.

Get a Quote Now